Unitor HPC Extreme 520 Specifications Page 125

  • Download
  • Add to my manuals
  • Print
  • Page
    / 211
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 124
Technical data
51
Cooling system
Type .......................................................................... Pressurized, sealed
Pressure cap, max. opening pressure:
TD420VE/TAD420VE/TAD620VE/
TD520GE/TAD530/531GE/
TAD520VE/TAD720VE/TAD732GE
TAD721VE/TAD733GE/TAD722VE: ....................... 90 kPa (13 psi)
1)
TD720GE/TAD730/731GE, TAD532GE: ................. 60 kPa (8.7 psi)
1)
Refers to VE engines which are not equipped with a pressure valve at the factory.
Volume (engine)
TD420VE/TAD420VE: ............................................. 4,7 liter (1.24 US gal)
TAD620VE: ............................................................. 6 liter (1.58 US gal)
TD520GE/TAD530/531GE/TAD520VE: ................... 7,2 liter (1.9 US gal)
TAD720VE/TD720GE/TAD730/731GE/
TAD732GE/TAD721VE/TAD733GE/TAD722VE: ..... 9,8 liter (2.59 US gal)
Volume (engine + radiator and hoses)
TD520GE: ............................................................... 17,5 liter (4.62 US gal)
TAD530/531GE: ...................................................... 19,7 liter (5.2 US gal)
TD720GE ................................................................ 22 liter (5.8 US gal)
TAD730/731GE, TAD532GE ................................... 23,8 liter (6.3 US gal)
TAD732GE/TAD733GE ........................................... 27,3 liter (7.2 US gal)
Thermostat
Quantity and type ....................................................... 1 piston thermostat
Opening temperature
TD420VE/TAD420VE/TAD620VE/
TD520GE/TAD530/531GE/
TD720GE/TAD730/731GE, TAD532GE: ................. 83° C (181° F)
TAD520VE/TAD720VE/TAD732GE/
TAD721VE/TAD733GE/TAD722VE: ....................... 87° C (189° F)
Fully open at
TD420VE/TAD420VE/TAD620VE/
TD520GE/TAD530/531GE/
TD720GE/TAD730/731GE, TAD532GE: ................. 95° C (203° F)
TAD520VE/TAD720VE/TAD732GE/
TAD721VE/TAD733GE/TAD722VE: ....................... 102° C (216° F)
Coolant filter
Quantity .................................................................. 1
Electrical system
System voltage .......................................................... 24 V (standard), 12 V (option)
123/209
Page view 124
1 2 ... 120 121 122 123 124 125 126 127 128 129 130 ... 210 211

Comments to this Manuals